Introduction
A urinalysis is one of the most common tests a veterinary technician runs in the clinic. It is part of the minimum database, along with the complete blood count and chemistry panel, and it tells the veterinarian about the urinary tract and about other body systems, such as the liver and red cell destruction.112
A complete urinalysis has four parts: physical (visual) assessment, urine specific gravity (USG), the dipstick (chemical) test and the sediment exam under the microscope.3 This guide covers how to collect and store the sample, how each part is done, which dipstick pads you can trust in animals, and how to recognize crystals, casts and cells. Most errors in urinalysis come from handling, not from the patient, so technique matters.
Key facts
- Cystocentesis gives the cleanest sample and is the preferred method for urine culture. It can add red cells (microscopic hematuria).212
- Examine urine within 30 minutes. If you cannot, refrigerate it, then bring it back to room temperature before testing.12
- Measure USG with a refractometer. Calibrate it with distilled water so it reads 1.000.111
- The dipstick pads for specific gravity, leukocytes (leukocyte esterase), nitrite and urobilinogen are not valid or not useful in animals.13
- Isosthenuria is a USG of 1.008 to 1.012. Hyposthenuria is a USG below 1.008.4
- Centrifuge the sediment at low speed, examine it unstained with the condenser lowered, and scan at 10× then 40×.13
- Struvite crystals look like "coffin lids"; calcium oxalate dihydrate looks like an envelope; ammonium biurate looks like a brown "thorn apple".6
- Crystalluria is not the same as urolithiasis (bladder stones), and crystals can form in the tube after collection.16
How the VTNE tests this
- Perform the test: Domain 4 Task C lists urinalysis among the laboratory tests a technician performs. K24 covers sample collection, handling, storage and shipping; K25 covers laboratory methods; K27 covers normal and abnormal results.15
- Choose the collection method: which method to use for a culture, and how each method changes cells and bacteria in the sediment.
- Identify: a crystal, cast or cell from a description or image of its shape.
- Troubleshoot: why an old or cold sample gives wrong results, or why a dipstick pad should be ignored.
- Calculate: a USG from a diluted sample that was off the refractometer scale.
Core concepts
How the collection method changes the result
Always record how the urine was collected, because the method changes what you see.2
- Free catch (voided): easy and safe. A mid-stream catch reduces contamination, but bacteria, squamous cells and debris from the distal urethra, genital tract and skin can still appear.212 Give owners a clean container with a tight lid; containers from home may hold detergent, food or drug residue.12 Urine from the floor or litter box is the poorest sample and may contain fecal material.2
- Catheterization: a sterile catheter is passed after aseptic preparation. It can slough extra transitional epithelial cells and cause mild bleeding, and it can carry bacteria into the bladder.212
- Cystocentesis: a needle is passed through the body wall into the bladder. It is the cleanest method and the preferred one for culture.212 It can cause microscopic hematuria: the urine still looks yellow, yet more than 100 RBC per high power field may be seen.2
Bacteria in a cystocentesis sample are significant at any number, because bladder urine is normally sterile. Small numbers of bacteria in a voided or catheter sample may be contamination.19
Time and temperature
Urine changes as it sits. With delay, pH rises, bacteria multiply, cells and casts break down, and bilirubin and ketones degrade.2 Merck advises evaluating urine within 30 minutes; if that is not possible, refrigerate it.1 Refrigeration does not alter pH or specific gravity, but it can make crystals precipitate.1 Calcium oxalate and struvite crystals can both develop during storage, even if they were absent in the fresh sample.2 Always warm refrigerated urine to room temperature before testing; USG and the dipstick need room-temperature urine.13
The time of day also matters. Morning (fasting) samples tend to have a higher USG, a lower pH and more formed elements than afternoon samples.2
Urine specific gravity
USG compares the density of urine with that of pure water, so it has no units.411 It shows whether the kidneys can concentrate or dilute urine. The veterinarian always reads it alongside hydration status and blood urea nitrogen and creatinine.14 Use a refractometer made for veterinary samples. Many have a separate scale for cats; use the dog scale for other species.1
Large amounts of glucose or protein in the urine falsely raise the USG reading.411 Radiographic contrast agents such as iohexol can raise it too, for 24 to 48 hours after a study.4 This is one reason urine should ideally be collected before treatment, including IV fluids, is started.3
| Term or species | USG | What it means |
|---|---|---|
| Hyposthenuria | Below 1.008 | Urine more dilute than plasma. The kidney can dilute but is not concentrating. |
| Isosthenuria | 1.008 to 1.012 | Same concentration as plasma. In a dehydrated or azotemic animal, the kidney is neither concentrating nor diluting. |
| Dog: usual range | 1.015 to 1.045 | "Adequate" concentration in an azotemic dog is above 1.030. |
| Cat: usual range | 1.035 to 1.060 | "Adequate" concentration in an azotemic cat is above 1.040. |
| Large animals: usual range | 1.015 to 1.030 | "Adequate" concentration in an azotemic large animal is above 1.025. |
Source: eClinPath, Concentrating ability (Cornell University).4 Cutoffs vary between references, so use your laboratory's values.
The dipstick (reagent strip)
A dipstick is a plastic strip with pads that change color when an analyte is present. Results are semiquantitative (negative, trace, 1+ and so on).13 The strips are designed for human urine. In animals you report pH, protein, glucose, ketones, bilirubin and blood (heme).15 A 2023 study in dogs found poor agreement between visual and analyzer readings for the leukocyte pad and for specific gravity.13
| Pad | Detects | Use in animals | Watch for |
|---|---|---|---|
| pH | Acid or alkaline urine | Use, but only accurate to about 0.5 unit | Rises in old samples and with urease-producing bacteria |
| Protein | Mainly albumin | Use; read against USG | False positive in alkaline urine and with quaternary ammonium or chlorhexidine |
| Glucose | Glucose (glucose oxidase) | Use | False positive with hydrogen peroxide or bleach; false negative with high vitamin C |
| Ketones | Acetoacetic acid and acetone | Use | Does not detect beta-hydroxybutyrate; trace reactions are often false |
| Bilirubin | Conjugated bilirubin | Use | Small amounts can be normal in concentrated dog urine; abnormal in cats |
| Blood (heme) | Intact RBCs, hemoglobin, myoglobin | Use; confirm with sediment | Discolored urine may give false positives |
| Specific gravity | Specific gravity estimate | Do not use | Use the refractometer instead |
| Leukocytes | Leukocyte esterase | Do not use | Count WBCs in the sediment instead |
| Nitrite | Some bacteria | Do not use | Look for bacteria in the sediment; culture to confirm |
| Urobilinogen | Urobilinogen | Not useful | Not specific enough to be clinically useful |
Sources: Merck Veterinary Manual, Urinalysis; eClinPath, Chemical constituents and Overview; Smyroglou and others, 2023.13513
Protein must always be read against USG. A trace of protein in concentrated urine matters less than the same trace in dilute urine.1 In urine with a USG below 1.015, even trace to 1+ protein is excessive.5 When the veterinarian needs a number, the urine protein to creatinine ratio (UP:UC) is measured on a chemistry analyzer.5
Glucose normally stays out of urine because the kidney reabsorbs it until blood glucose passes the renal threshold: above 180 mg/dL in most species and above 240 mg/dL in cats.1 If the glucose pad is positive, a blood glucose should be checked.1
A positive blood pad can mean intact red cells, hemoglobin or myoglobin. Look at the sediment: red cells mean hematuria. With no red cells, look at the plasma. Pink to red plasma points to hemoglobin from red cells broken down in the blood vessels; clear plasma points to myoglobin from muscle.1
Sediment: cells, casts and organisms
Report red and white cells as the number per high power field (HPF, 40× objective). Up to about 5 RBC/HPF and fewer than 5 WBC/HPF are commonly accepted as normal, though this depends on the collection method.8 White cells are a little larger than red cells and have grainy cytoplasm.1 Transitional epithelial cells line the bladder and proximal urethra; they look like large white cells. Squamous epithelial cells are large flat cells seen in voided samples.18 Fat droplets are common in dog and cat urine and can be mistaken for red cells; they vary in size and float in a different plane of focus.1 Sperm may be normal in urine from intact male dogs.1
Casts are cylinders of mucoprotein that form in the renal tubules and may trap cells. Count them per low power field (LPF, 10× objective).17 Hyaline casts are clear, with parallel sides and rounded ends; they are hard to see without lowering the light. A few hyaline or granular casts can be normal. Cellular, coarsely granular and waxy casts, even in low numbers, indicate kidney damage.17 Casts dissolve with time, especially in dilute or alkaline urine, so a delayed sample can hide them.7
Small amorphous crystals and debris can look like bacteria. A Gram stain helps, and aerobic culture is best to confirm a bacterial infection.16
Crystals
Crystals form when urine is supersaturated with a substance. Which type forms depends on urine pH, concentration, temperature, and time since collection.16 Report them as few, moderate or many. Judge large crystals such as struvite at low power and small crystals such as calcium oxalate dihydrate at high power.6
| Crystal | Shape and color | Favored pH | Clinical link |
|---|---|---|---|
| Struvite (magnesium ammonium phosphate, triple phosphate) | Colorless 3-D prisms, "coffin lids" | Neutral to alkaline | Most common crystal in dogs and cats; often in healthy animals. Urease-producing bacteria promote it. |
| Calcium oxalate dihydrate | Colorless squares with an "X", "envelopes" | Any pH | Often in normal urine; can form during storage. Seen in some ethylene glycol cases. |
| Calcium oxalate monohydrate | Dumbbell or oval forms; flat six-sided "picket fence" form | Not stated in our sources | Picket fence form is linked to ethylene glycol poisoning in dogs and cats. |
| Ammonium biurate (ammonium urate) | Brown or yellow-brown spheres with spikes, "thorn apples" | Neutral to acidic | Portosystemic shunt and other liver disease; normal in Dalmatians and English Bulldogs. |
| Bilirubin | Yellow needles or granules, often on cells | Not given; follows bilirubinuria | Can be normal in small numbers in concentrated dog urine; abnormal in cats, horses and cattle. |
| Cystine | Colorless flat hexagons | Acidic | Cystinuria, an inherited tubular defect, mostly in male dogs. |
| Calcium carbonate | Large spheres with radial lines, colorless to yellow-brown | Herbivore urine (usually alkaline) | Normal in horses, rabbits, guinea pigs and goats; not seen in dogs or cats. |
Sources: eClinPath, Crystals; Merck Veterinary Manual, Urinalysis.16 Merck gives the pH range for struvite (alkaline) and cystine (acidic).
Two points matter most. First, crystalluria is not the same as urolithiasis: crystals can appear without stones and stones can form without crystals.1 Second, crystals can form in the tube after collection, so a fresh sample examined at room temperature gives the truest picture.16 In dogs, struvite crystals without a urease-producing bacterial infection are not linked to struvite stones; cats can form struvite stones without infection.1
The ethylene glycol (antifreeze) link is the urgent one. Its toxic metabolite, oxalate, binds calcium and forms calcium oxalate crystals in the renal tubules.14 Picket fence calcium oxalate monohydrate crystals are frequently associated with ethylene glycol poisoning in dogs and cats, but they are not seen in every case.6 If you see them, tell the veterinarian at once; treatment is time critical (see the emergency and toxicology guides in Domain 8).14
Procedure or technique
Assisting with cystocentesis (blind technique)
- Restrain the patient in lateral recumbency; some dogs can be sampled standing.12
- The person sampling palpates and isolates the bladder in the caudal abdomen to make sure it holds enough urine.12
- The needle is inserted at about a 45 degree angle without suction. At the right depth the plunger is drawn back slowly.12
- Pressure on the plunger is released before the needle is withdrawn.12
- For culture, change the needle before transferring urine into a tube, and refrigerate the sample until it is shipped.12
Ultrasound-guided cystocentesis follows the same steps while the bladder is viewed on screen.12 Urine leak and bleeding after cystocentesis are rare.12
Running the urinalysis
- Label and record the patient, date, time and collection method.2
- Physical exam: mix the sample and record color and turbidity (clear, slightly cloudy, cloudy, opaque or flocculent). Normal urine is yellow to amber and clear.110 Color is subjective and is not a substitute for USG.4
- Dipstick: use uncentrifuged, room-temperature urine. Dip the strip briefly or drip urine on each pad, blot the edge on gauze, and hold the strip flat so urine does not run between pads. Read each pad at the time the maker states. If the urine is very bloody or discolored, use the supernatant after spinning.13 Keep the bottle tightly capped and discard expired strips.1
- Centrifuge 3 to 5 mL of urine in a conical tube at low speed, about 1,000 to 1,500 rpm for 3 to 5 minutes.1 Try to use the same volume every time, because the semiquantitative sediment counts depend on it.3
- USG: put 1 to 5 drops of supernatant on the calibrated refractometer prism, close the cover and read the line where light meets dark.311 Clean the prism with distilled water and a soft cloth after each use.11
- Prepare the sediment: pour off the supernatant, leaving about 0.5 mL. Resuspend the pellet by tapping the tube, place a drop on a slide and add a coverslip.1
- Examine unstained, with the condenser lowered or the iris diaphragm closed for contrast. Scan the whole coverslip at 10× for casts, large crystals and parasite eggs, then check structures and at least several fields at 40× for cells, small crystals and bacteria.13 Stains such as new methylene blue help identify cells but can add precipitate and dilute the sample.1
Flowchart
Species differences
- Dog: urine is usually acidic.1 A small amount of bilirubin, and a few bilirubin crystals, can be normal in concentrated urine.16 Dalmatians and English Bulldogs can have ammonium biurate crystals without liver disease.6 Male dogs are the easiest patients to catheterize.2
- Cat: urine is usually acidic and more concentrated than dog urine, with a usual USG of 1.035 to 1.060.14 Read USG on the cat scale of a veterinary refractometer.1 Bilirubin in cat urine is always abnormal.6 The renal threshold for glucose is higher than in dogs, above 240 mg/dL.1
- Horse: urine is usually alkaline and is often cloudy from mucus and calcium carbonate crystals, which are normal.1610 Equine urine can turn brown after standing.1
- Ruminants: urine is usually alkaline. Calcium carbonate crystals are normal in goats, and calcium oxalate crystals are common in healthy cattle.16 Ketonuria is a sign of ketosis in ruminants.1
- Rabbits and guinea pigs: calcium carbonate crystals are normal.6
Calculation
Worked example: a USG off the scale. A cat's urine reads above the top of the refractometer scale. Papajeski describes diluting 1 drop of urine with 1 drop of distilled water, mixing, reading the diluted sample, then multiplying the digits after the decimal point by 2.11
Diluted reading: 1.034
Digits after the decimal: 034 (that is, 34 thousandths)
34 × 2 = 68 thousandths
Estimated USG = 1.000 + 0.068 = 1.068
The dilution is 1 part urine in 2 parts total, so the factor is 2. Many clinics simply report "greater than" the scale limit (for example, more than 1.060) instead.11 USG has no units, so none appear in the answer.
Safety, legal and client education
- Wear gloves when handling urine; Papajeski lists gloves for protection against zoonotic disease.11
- Do not clean the refractometer prism with abrasive cleaners or cloths; scratches ruin readings.1112
- Owners collecting at home: give a clean container with a tight lid, ask for a mid-stream sample, and ask them to bring it in quickly or refrigerate it.112
- Do not use plastic red-top tubes for storing urine; they can introduce crystal-like artifacts. Glass plain tubes or sterile containers are suitable.2
- When shipping, tell the outside laboratory if any preservative such as formalin was added, because it affects staining.1
- Antifreeze is a household poison. If a client mentions possible exposure, alert the veterinarian immediately.14
Common mistakes and exam traps
- Reading USG from the dipstick. The SG pad is not valid in animals; use the refractometer.1
- Trusting a negative leukocyte pad. The leukocyte esterase pad is not valid in animals; count white cells in the sediment.15
- Testing cold urine. Bring refrigerated urine to room temperature first.1
- Calling crystals "stones". Crystalluria is not urolithiasis, and stored urine grows crystals.12
- Calling cystocentesis blood a bleed. Cystocentesis can add many red cells to yellow urine.2
- Mixing up the oxalates. The envelope is dihydrate; the picket fence is monohydrate and is the ethylene glycol form.6
Quick review
- A urinalysis has four parts: physical exam, USG, dipstick and sediment.
- Cystocentesis is the cleanest method and the first choice for culture.
- Bacteria in a cystocentesis sample are significant at any number.
- Examine within 30 minutes or refrigerate, then warm to room temperature.
- Storage raises pH, grows bacteria, breaks down casts and cells, and forms crystals.
- Calibrate the refractometer to 1.000 with distilled water; read the cat scale for cats.
- Isosthenuria is 1.008 to 1.012; hyposthenuria is below 1.008.
- Ignore the dipstick SG, leukocyte, nitrite and urobilinogen pads in animals.
- Read dipstick protein against USG; trace protein in dilute urine is significant.
- Spin 3 to 5 mL at low speed, examine unstained with the condenser lowered, 10× then 40×.
- Count casts per LPF and cells per HPF; cellular and waxy casts mean kidney damage.
- Struvite is a coffin lid, CaOx dihydrate an envelope, CaOx monohydrate a picket fence.